Booking Schedule of the
(6.0 MeV EN-Tandem, 2.5 MV Van der Graaff, Data - Acquisition Facilities)


Dec - 2002

Below in blue are the backed up projects.

Key
Scheduled
Run after rescheduling
Run as scheduled
Date
(scheduled)
Date
(run)
Project / Institutions Number Spokesperson / team Beam/Energy Facility / DAQ Result
Dec 2-9

Dec 2-9

Maintainance

O Pekar,
T Hollander,
E Rood


Chiller plant broke down -  overhauled
Switcher magnet vacuum system leak - repaired
Gas redryed
AMS line gauges cleaned
Dec 9-11
Dec 9-11

Test Tandem

SH Connell,
O Pekar
3.2 MeV p

Transmission poor
Dec 9 - 11


Dec 12-24

Maintainance

O Pekar,
T Hollander,
E Rood, SH Connell,
Students


Re-open machine
Repair HE colomn current connector
Re-align stripper canal, LE injection, HE transport
Ocerhaul entire stripper gass system, find bad high current connections
Dec 30
Dec 30
Maintainance

E Rood


Restart all pumping systems
    Thin single crystal diamond project :
Implantation - anneal and etch lift-off technique
  C Levitte
(Schonland)
Sbu Mabizela
SH Connell
D Rebuli
E Sideras-Haddad
12C / 9 MeV 0o High Energy Heavy Ion Implantation beam line  
    Develop AMS capability - prepare for separation measurement of 13C, 14C, and 14N   Tjatje Tjebane
SH Connell. 
E Sideras-Haddad
E Rood, O Pekar, T Hollander, R Chirwa
12C5+ / 19.8 MeV

13C5+ / 19.8 MeV

Tandem - 45o E beam line.
- newly installed MS line
 
    uPIXE study of blood samples from aesophogus cancer patients   Ray
(Oncology Dept)
E Sideras-Haddad
SH Connell
Proton / 3.2 Mev Tandem - 30o W beam line
Microprobe 
OMDAQ
 
    Study of hydrogen mobility in diamond (using deuterium isotope)   A Naran
(U. Eduardo Mondlane)
SH Connell
E Sideras-Haddad
JPF Sellschop
D Rebuli
A DaCosta
M Dalton
12C / 12 MeV Tandem - 30o W beam line
Microprobe 
COLLECT-DAQ
 
    Characterisation of H, N and O distributions in growth zones of ultra-high-quality synthetic type Ia diamond   D Dube
D Rebuli
JPF Sellschop
(Schonland)
A DaCosta
SH Connell
E Sideras-Haddad
4He / 3-5 MeV Tandem - 30o W beam line
Microprobe 
OMDAQ
Develop microscopy for in situ N and O in diamond
    Radiation Damage study of Diamond Detectors   A DaCosta
(Schonland)
JPF Sellschop
SH Connell
E Sideras-Haddad
12C / 12 MeV
Proton / 3.2 MeV
Tandem - 30o W beam line
Microprobe 
OMDAQ
 

Last updated  : 4 February  2003